Installing and connecting a QUA6 PFTU

553-3041-210
Standard 4.00
Installing and cross-connecting a Power Fail Transfer Unit
The following procedures are provided in this chapter:
1
Procedure 115: "Installing and connecting a QUA6 PFTU" on
2
Procedure 116: "Connecting an analog (500/2500-type) telephone to a
PFTU" on
page 450
3
Procedure 117: "Connecting a Trunk to a PFTU" on
Follow Procedure 115 to install and connect a QUA6 PFTU. Refer to the
equipment layout plan for the location of the PFTU.
Note: The QUA6 PFTU operates with loop-start and ground-start
Central Office trunks. With ground start trunks, the associated telephone
set must have a ground start button.
Procedure 115
Installing and connecting a QUA6 PFTU
1
Install the PFTU on the wall near the system cross-connect terminal.
Fasten the PFTU in position with four screws.
2
Install an NE-A25B-type 25-pair cable from connector J1 on the faceplate
of the PFTU to its assigned location at the cross-connect terminal.
3
Label the pairs of the J1 cable on the cross-connect terminal block as
shown in Figure 150 on
Figure 150
J1 cable labels
Pairs
Pairs
1 to 4
1 to 4
Control
PFT1
Label the pairs on the terminal block as shown. If using
BIX blocks, attach the appropriate designation strip.
September 2007
page
442.
Pairs
Pairs
Pairs
1 to 4
1 to 4
1 to 4
PFT2
PFT3
PFT4
page 442
page 452
Pairs
Pairs
1 to 4
1 to 4
PFT1
PFT5
Power