Standard 4.00
Installing and cross-connecting a Power Fail Transfer Unit
Procedure 116
Connecting an analog (500/2500-type) telephone to a PFTU
1
Locate the telephone terminations on the cross-connect terminal.
2
Connect one end of the cross-connect wire to the leads of the telephone.
3
Locate the PFTU connections (unit PFTU 1 through PFTU 5) assigned to
this telephone at the cross-connect terminal. See Table 58 on
4
Connect the other end of the cross-connect wire to the pair assigned to
the telephone on the PFTU.
5
Connect a second cross-connect wire to the pair assigned to the Line card
on the PFTU.
6
Locate the Line card terminations on the cross-connect terminal.
7
Connect the other end of the cross-connect wire to the assigned TN
terminal block.
Table 58
Power Fail Transfer Unit connections (Part 1 of 3)
Function
PFT 1
September 2007
QUA6 J1 Cable
Pair
Color
5T
W-S
5R
S-W
6T
R-BL
6R
BL-R
7T
R-O
7R
O-R
8T
R-G
8R
G-R