Printing Survivable Mg 1000T Expansion Parameters; Configuring Alternate Primary Controller - Nortel 1000E Installation And Configuration Manual

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Configuring MG 1000T survivability and alternate primary controller

Printing Survivable MG 1000T Expansion parameters

Configuring Alternate primary controller

5
Configure the SWOTO.
Configure the SWOTO separately for each MG 1000T Expansion.
The SWOTO command is configured in LD 117:
CHG SWOTO <cab#> <value>
cab# = 1-4, MG 1000T Expansion
value = 2 - (120) - 600 seconds
For point-to-point connection (MG 1000T Expansions that are not
connected over a LAN), Nortel recommends that you set the timer to a low
value to minimize service interruption.
The following Print commands, available in LD 117, print the MG 1000T
Expansion parameters and Survivability for all, or specified, Survivable
MG 1000T Expansion
PRT SURV cab
Where:
cab = 1 to 4,
PRT CAB cab
Where:
cab = 1 to 4,
Procedure 120
Configuring the IP telephony node for Alternate primary controller
1
Log in to Element Manager, if you are not already logged in.
2
Select IP Telephony > Nodes: Servers, Media Cards > Configuration
from the navigator.
The Node Configuration web page opens, as shown in Figure 99 on
page
322.
Communication Server 1000E
End of Procedure
.
MG 1000T Expansion
MG 1000T Expansion
Page 473 of 488
Installation and Configuration

Advertisement

Table of Contents
loading

Table of Contents