Nortel 1000E Installation And Configuration Manual page 148

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Page 148 of 488
553-3041-210
Standard 4.00
Installing software on the CS 1000E
From active Call Server 1, perform the following tests on Call Server 0:
1
Perform a redundancy sanity test:
LD 135
STAT CPU
TEST CPU
2
Check the LCD states
a.
Perform a visual check of the LCDs.
b.
Test and LCDs:
LD 135
TEST LEDs
DSPL ALL
c.
Check that the LCD display matches the software check.
3
Test the System Utility card
LD 135
STAT SUTL
TEST SUTL
4
Test system redundancy and media devices:
LD 137
TEST RDUN
DATA RDUN
STAT FMD
STAT RMD
5
Clear the display and minor alarms on both Call Servers:
LD 135
CDSP
CMAJ
CMIN ALL
6
Check dial tone.
September 2007
Get status of CPU and memory
Test the CPU
Test LEDs
Load program
Get the status of the System Utility card
Test the System Utility card
Load program
Test redundancy
Test database integrity
Status of one or both Fixed Media Devices
(FMD)
Status of one or both Removable Media Devices
(RMD)
Load program
Clear the displays on the cores
Clear major alarms
Clear minor alarms