Nortel 1000E Installation And Configuration Manual page 314

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Page 314 of 488
553-3041-210
Standard 4.00
Installing and cross-connecting a trunk card
Note: The speech pairs on the NT5K19 card are polarity-insensitive.
The E&M signaling pairs, however, are polarity-sensitive. Make sure the
ground side of the trunk is connected to the A leg of the NT5K19 circuit.
Make sure the -50 Volt side of the trunk is connected to the B leg.
Table 34
NT5K19 2W paging mode terminations
Pair
T0
R0
A
PG
T1
R1
A
PG
T2
R2
A
PG
T3
R3
A
PG
Table 35
NT5K19 2W Type 1 mode terminations (Part 1 of 2)
Pair
T0
R0
E
M
September 2007
Pins
Pair color
27
W-O
2
O-W
29
W-BR
4
BR-W
31
R-BL
6
BL-R
33
R-G
8
G-R
35
R-S
10
S-R
37
BK-O
12
O-BK
39
BK-BR
14
BR-BK
41
Y-BL
16
BL-Y
Pins
Pair color
27
W-O
2
O-W
28
W-G
3
G-W
Unit
0
1
2
3
Unit
0