Configuring Virtual Superloops - Nortel 1000E Installation And Configuration Manual

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Configuring virtual superloops

Table 51
LD 97 – Configure a Virtual Superloop.
Prompt
Response
REQ
CHG
TYPE
SUPL
SUPL
Vxxx
Follow Procedure 103 to configure the virtual superloops. For more details on
virtual superloops, see IP Line: Description, Installation, and Operation
(553-3001-365).
Procedure 103
Configuring virtual superloops
1
Access LD 97. Enter the command:
LD 97
2
Enter responses shown in Table 51.
Comment
Change existing data
Superloop
V stands for a virtual superloop and xxx is the number of the virtual
superloop.
xxx = 0-252 in multiples of four for MG 1000E
xxx = 96-112 in multiples of four for MG 1000T (See Table 52)
Communication Server 1000E
Installing and configuring IP Phones
End of Procedure
Page 410 of 488