Figure 50
First boot of a new system
CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)
=====================================================================
The filesystems verification failed! (This is normal for a new
system.)
The hard disk must be (re)partitioned and (re)initialized. This will
erase all data on the hard disk. The system will then reboot and
the Install Tool will restart.
Please enter:
<CR> -> <a> - Partition and initialize the hard disk, then reboot.
Enter Choice> a
553-3041-210
Standard 4.00
Installing and configuring the Signaling Server software
The system verifies the file systems.
When the software runs for the first time on a new system, the hard
disk will not be partitioned, so the test normally fails. Upon failure, the
menu in Figure 50 appears.
a.
Enter a to start the new installation.
The system displays the messages:
Partitioning hard disk ...
Hard disk partitioning succeeded.
Creating filesystems ...
Filesystems creation succeeded.
Rebooting system ...
b.
The Install Tool banner screen (Figure 49 on
reappears. Press <CR> to verify the filesystems.
The disk check reports:
Filesystems verification succeeded.
c.
Confirm or enter the date and time (Figure 51).
September 2007
page
175)