82 Clearing faults
Table 23
Signaling Server Diagnosis (cont'd.)
Condition
ELAN or TLAN network interface
Link light not active
Signaling Server unable to boot
from hard drive
Signaling Server not responding
through serial port.
Signaling Server boots and then
stops.

Clearing MG 1000E faults

Clearing ELAN network interface faults
On each MG 1000E, the MGC card connects to the ELAN subnet through
the ELAN network interface. A CAT5 or 100BaseT Ethernet cable
connects the ELAN network interface to a Layer 2 switch on the ELAN
subnet. This provides speech path switching and transmit and receive
signaling messages.
Faults related to the ELAN network interface can cause system
initializations, disable conference capability, or disable all terminal
connections (such as trunks and telephones) on a card. ELAN network
interface faults can also make functional equipment appear faulty.
Table 24 "ELAN network interface fault indicators" (page 83)
indicators for MG 1000E ELAN network interface faults.
Possible Cause
Bad connection to Ethernet
switch
Failed network interface
Hard drive not formatted
Hard drive with bad sectors
Hard drive failed
Software failed
No software loaded
Nortel Communication Server 1000
Communication Server 1000E Maintenance
NN43041-700 02.07 22 December 2009
Copyright © 2004-2009 Nortel Networks. All Rights Reserved.
Action
Check power on Ethernet
switch.
Check CAT5 Ethernet cable.
Check Ethernet switch port.
Replace Signaling Server.
Install software. See
Communication Server 1000E
Installation and Commissioning
(NN43041-310).
Install software and use disk
check option. Replace Server if
disk check fails.
Replace Signaling Server
Reset Signaling Server
Load software. See
Communication Server 1000E
Installation and Commissioning
(NN43041-310).
provides fault