Siemens CU240B-2 Parameter Manual page 501

Table of Contents

Advertisement

Main setpoint
p1070 [C]
(755[0])
Suppl setpoint
p1075 [C]
Jog 1 n_set
-210000.000 ... 210000.000 [1/min]
p1058 [D] (150.000)
Jog 2 n_set
-210000.000 ... 210000.000 [1/min]
p1059 [D] (-150.000)
n_set_fixed eff [1/min]
r1024
[3010]
Fixed speed setpoints
raise
Mop setp after RFG [1/min]
r1050
lower
Motorized potentiometer
[3020]
1
2
Overviews
Setpoint channel
STW seq_ctrl
r0898
r0898
.8
STW seq_ctrl
r0898
r0898
.9
0 0
+
+
p1071
0 1
(0)
p1076
1 0
1 1
[3030]
Main/supplementary setpoint, setpoint
scaling, jogging
r1119
RFG setp at inp [1/min]
[3060]
Basic ramp-function
generator
[3070]
Expanded ramp-function
generator
3
4
Setp after limit
n_set_1
[1/min]
+ / -
r1114
pos
neg
(-1)
[3040]
Direction of rotating
limiting/changeover
RFG selection
0 ... 1
p1115 (1)
n_set_4
0
1
ZSW
n_set_5
[3080]
Ramp-function generator selection,
status word, tracking
Simulate ramp-function generator
5
6
FP_1550_97_51.vsd
13.12.2010
V4.4
RFG setpoint
at the input
[3050]
Skip (suppression)
bandwidth and speed limiting
RFG n_set at outp [1/min]
r1150
n_ctrl n_set 1
p1155 [C]
n_ctrl setp sum [1/
+
min]
(0)
r1170
+
n_ctrl n_set 2
+
[1700.1]
p1160 [C]
(0)
n_ctrl n_set [1/min]
r1438
+
RFG ZSW
n_act
r1199
r1199
Ramp-function
M_limit
generator
tracking
7
8
Function diagram