Parameters
List of Parameters
r9571
SI Motion acceptance test status (processor 1) / SI Mtn acc_status
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
0000 hex
Description:
Displays the status of the acceptance test mode.
Value:
0:
12:
13:
15:
172:
Dependency:
Refer to: p9558, p9570
Refer to: C01799
p9581
SI Motion brake ramp reference value (processor 1) / SI Mtn ramp ref P1
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
600.0000 [rpm]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9582, p9583
p9582
SI Motion brake ramp delay time (processor 1) / SI Mtn ramp t P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
10.00 [ms]
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9581, p9583
p9583
SI Motion brake ramp monitoring time (processor 1) / SI Mtn rp t_mon P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.50 [s]
Description:
Sets the monitoring time to define the brake ramp.
The rate of rise of the brake ramp depends upon p9581 (reference value) and p9583 (monitoring time).
Dependency:
Refer to: p9581, p9582
1-356
[00 hex] Acc_mode inactive
[0C hex] Acc_mode not possible due to POWER ON fault
[0D hex] Acc_mode not possible due to incorrect ID in p9570
[0F hex] Acc_mode not possible due to expired Acc_timer
[AC hex] Acc_mode active
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
00AC hex
Calculated: -
Scaling: -
Unit selection: -
Max
24000.0000 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
99000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00 [s]
Data type: Integer16
Data set: -
Factory setting
-
Data type: FloatingPoint32
Data set: -
Factory setting
1500.0000 [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
250.00 [ms]
Data type: FloatingPoint32
Data set: -
Factory setting
10.00 [s]