p2184[0...n]
Load monitoring speed threshold value 3 / n_thresh 3
Access level: 3
Can be changed: U, T
Units group: 3_1
Min
0.00 [rpm]
Description:
Sets the speed/torque envelope curve for load monitoring.
The envelope curve (upper and lower envelope curve) is defined as follows based on 3 speed thresholds:
p2182 (n_threshold 1) --> p2185 (M_threshold 1, upper), p2186 (M_threshold 1, lower)
p2183 (n_threshold 2) --> p2187 (M_threshold 2, upper), p2188 (M_threshold 2, lower)
p2184 (n_threshold 3) --> p2189 (M_threshold 3, upper), p2190 (M_threshold 3, lower)
Dependency:
The following applies: p2182 < p2183 < p2184
Refer to: p2182, p2183, p2189, p2190
p2185[0...n]
Load monitoring torque threshold 1, upper / M_thresh 1 upper
Access level: 3
Can be changed: U, T
Units group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2185 > p2186
Refer to: p2182, p2186
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2186[0...n]
Load monitoring torque threshold 1, lower / M_thresh 1 lower
Access level: 3
Can be changed: U, T
Units group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2186 < p2185
Refer to: p2182, p2185
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2187[0...n]
Load monitoring torque threshold 2, upper / M_thresh 2 upper
Access level: 3
Can be changed: U, T
Units group: 7_1
Min
0.00 [Nm]
Description:
Sets the speed/torque envelope curve for load monitoring.
Dependency:
The following applies: p2187 > p2188
Refer to: p2183, p2188
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: p0505
Max
210000.00 [rpm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
20000000.00 [Nm]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
1500.00 [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
10000000.00 [Nm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.00 [Nm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
10000000.00 [Nm]