Parameters
List of Parameters
p0201[0...n]
Power unit code number / PU code no
Access level: 3
Can be changed: C(2)
Units group: -
Min
0
Description:
Sets the actual code number from r0200 to acknowledge the power unit being used.
When commissioned for the first time, the code number is automatically transferred from r0200 into p0201.
Note:
The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers
are identical (p0010 = 2).
When the code number is changed, the connection voltage (p0210) is checked and, if necessary, adjusted.
r0203[0...n]
Actual power unit type / PU actual type
Access level: 3
Can be changed: -
Units group: -
Min
2
Description:
Displays the type of power unit found.
Value:
2:
3:
4:
5:
6:
7:
100:
101:
102:
112:
113:
114:
115:
116:
118:
120:
133:
150:
200:
250:
260:
300:
350:
400:
Note:
For parallel circuit configurations, the parameter index is assigned to a power unit.
1-44
MICROMASTER 440
MICROMASTER 411
MICROMASTER 410
MICROMASTER 436
MICROMASTER 440 PX
MICROMASTER 430
SINAMICS S
SINAMICS S (value)
SINAMICS S (combi)
PM220 (SINAMICS G120)
PM230 (SINAMICS G120)
PM240 (SINAMICS G120)
PM250 (SINAMICS G120)
PM260 (SINAMICS G120)
SINAMICS G120 Px
PM340 (SINAMICS S120)
SINAMICS G120C
SINAMICS G
SINAMICS GM
SINAMICS SM
SINAMICS SM120
SINAMICS GL
SINAMICS SL
SINAMICS DCM
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
65535
Calculated: -
Scaling: -
Unit selection: -
Max
400
Data type: Unsigned16
Data set: PDS
Factory setting
0
Data type: Integer16
Data set: PDS
Factory setting
-
© Siemens AG 2011 All Rights Reserved