p1075[0...n]
CI: Suppl setpoint / Suppl setpoint
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the supplementary setpoint.
Dependency:
Refer to: p1076, r1077, r1078
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the supplementary setpoint.
r1077
CO: Supplementary setpoint effective / Suppl setpoint eff
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the effective supplementary setpoint. The value shown is the additional setpoint after scaling.
r1078
CO: Total setpoint effective / Total setpoint eff
Access level: 3
Can be changed: -
Units group: 3_1
Min
- [rpm]
Description:
Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
p1080[0...n]
Minimum speed / n_min
Access level: 1
Can be changed: C(1), T
Units group: 3_1
Min
0.000 [rpm]
Description:
Sets the lowest possible motor speed.
This value is not undershot in operation.
Note:
The parameter value applies for both motor directions.
In exceptional cases, the motor can operate below this value (e.g. when reversing).
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: -
Unit selection: p0505
Max
19500.000 [rpm]
Parameters
List of Parameters
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
1
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
- [rpm]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
0.000 [rpm]