Siemens CU240B-2 Parameter Manual page 370

Table of Contents

Advertisement

Parameters
List of Parameters
p9763
SI password acknowledgement / SI ackn password
CU240E-2
Access level: 3
CU240E-2 DP
Can be changed: C(95)
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
0000 hex
Description:
Acknowledges the new Safety Integrated password.
Dependency:
Refer to: p9762
Note:
The new password entered into p9762 must be re-entered in order to acknowledge.
p9762 = p9763 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
r9765
SI Motion forced checking procedure remaining time (processor 1) /
SI Mtn dyn rem P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
- [h]
Description:
Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions inte-
grated in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
Refer to: p9705
Refer to: C01798
r9770[0...3]
SI version drive-integrated safety function (processor 1) / SI version Drv P1
CU240E-2
Access level: 3
CU240E-2 DP
Can be changed: -
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
-
Description:
Displays the Safety Integrated version for the drive-integrated safety functions on processor 1.
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Note:
Example:
r9770[0] = 2, r9770[1] = 60, r9770[2] = 1, r9770[3] = 0 --> Safety version V02.60.01.00
r9771
SI common functions (processor 1) / SI general fct P1
CU240E-2
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the supported Safety Integrated monitoring functions.
Processor 1 determines this display.
Bit field:
Bit
Signal name
00
STO supported via terminals
Dependency:
Refer to: r9871
Note:
STO: Safe Torque Off
1-370
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Calculated: -
Scaling: -
Unit selection: -
Max
- [h]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: Unsigned32
Data set: -
Factory setting
0000 hex
Data type: FloatingPoint32
Data set: -
Factory setting
- [h]
Data type: Unsigned16
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
No