Siemens CU240B-2 Parameter Manual page 486

Table of Contents

Advertisement

Parameters
Quick commissioning (p0010 = 1)
Table 1-7
Par.-No.
p1080
p1082
p1120
p1121
p1135
p1300
p1500
p1900
p2196
p3900
When p0010 = 1 is chosen, p0003 (user access level) can be used to select the parameters
to be accessed.
At the end of the quick commissioning sequence, set p3900 = 1 to carry out the necessary
motor calculations and clear all other parameters (not included in p0010 = 1) to their default
settings.
Note
This applies only in Quick Commissioning mode.
1-486
Quick commissioning (p0010 = 1), continued
Name
Minimum speed
Maximum speed
Ramp-function generator ramp-up time
Ramp-function generator ramp-down time
OFF3 ramp-down time
Open-loop/closed-loop control operating mode 2
Selecting the torque setpoint
Motor data identification and rotating
measurement
Torque utilization scaling
Completion of quick commissioning
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Access level
Can be
changed
1
C(1)T
1
C(1)T
1
C(1)UT
1
C(1)UT
2
C(1)UT
C(1)T
2
C(1)T
2
C(1)T
1
C(1,3)UT
1
C(1)
© Siemens AG 2011 All Rights Reserved