p1909[0...n]
Motor data identification control word / MotID STW
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the configuration for the motor data identification.
Bit field:
Bit
Signal name
00
Stator inductance estimate no measure-
ment
02
Rotor time constant estimate no measure-
ment
03
Leakage inductance estimate no measure-
ment
05
Determine Tr and Lsig evaluation in the time
range
06
Activate vibration damping
07
De-activate vibration detection
11
De-activate pulse measurement Lq Ld
12
De-activate rotor resistance Rr measure-
ment
14
De-activate valve interlocking time mea-
surement
15
Determine only stator resistance, valve volt-
age fault, dead time
Note:
The following applies to permanent-magnet synchronous motors:
Without de-selection in bit 11, in the closed-loop control mode, the direct inductance LD and the quadrature induc-
tance Lq are measured at a low current.
When de-selecting with bit 11 or in the U/f mode, the stator inductance is measured at half the rated motor current.
If the stator is inductance is not measured but is to be estimated, then bit 0 should be set and bit 11 should be de-
selected.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Parameters
List of Parameters
Data type: Unsigned16
Data set: MDS
Factory setting
0000 0000 0000 0000 bin
0 signal
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
-
-
-
-
-