p2088[0...4]
Invert binector-connector converter status word / Bin/con ZSW inv
CU240B-2
Access level: 3
CU240E-2
Can be changed: U, T
CU240E-2 F
Units group: -
Min
-
Description:
Setting to invert the individual binector inputs of the binector connector converter.
Index:
[0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
[4] = Free status word 5
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
Dependency:
Refer to: p2080, p2081, p2082, p2083, r2089
p2088[0...4]
Invert binector-connector converter status word / Bin/con ZSW inv
CU240B-2 DP
Access level: 3
CU240E-2 DP
Can be changed: U, T
CU240E-2 DP F
Units group: -
Min
-
Description:
Setting to invert the individual binector inputs of the binector connector converter.
Index:
[0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
[4] = Free status word 5
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
Dependency:
Refer to: p2080, p2081, p2082, p2083, r2089
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Inverted
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Factory setting
0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Data type: Unsigned16
Data set: -
Factory setting
[0] 1010 1000 0000 0000 bin
[1...4] 0000 0000 0000 0000 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1-267

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f

Table of Contents