Parameters
List of Parameters
p2210[0...n]
CO: Technology controller, fixed value 10 / Tec_ctr fix val 10
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 10 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2211[0...n]
CO: Technology controller, fixed value 11 / Tec_ctr fix val 11
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2212[0...n]
CO: Technology controller, fixed value 12 / Tec_ctr fix val 12
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2213[0...n]
CO: Technology controller, fixed value 13 / Tec_ctr fix val 13
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 13 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2214[0...n]
CO: Technology controller, fixed value 14 / Tec_ctr fix val 14
Access level: 2
Can be changed: U, T
Units group: 9_1
Min
-200.00 [%]
Description:
Sets the value for fixed value 14 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
1-300
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
200.00 [%]
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
100.00 [%]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
110.00 [%]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
120.00 [%]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
130.00 [%]
Data type: FloatingPoint32
Data set: DDS, p0180
Factory setting
140.00 [%]