r9409
Number of parameters to be saved / Qty par to save
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency:
Refer to: p0971
Note:
The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
r9451[0...29]
Units changeover adapted parameters / Unit_chngov par
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency:
Refer to: F07088
r9463
Set valid macro /
Access level: 3
Can be changed: -
Units group: -
Min
0
Description:
Displays the valid macro.
A value of 0 is displayed if a parameter set by a macro is changed.
p9484
BICO interconnections search signal source / BICO S_src srch
Access level: 3
Can be changed: U, T
Units group: -
Min
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency:
Refer to: r9485, r9486
r9485
BICO interconnections signal source search count / BICO S_src srchQty
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
1-346
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
999999
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
-
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: Unsigned16
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
0
Data type: Unsigned16
Data set: -
Factory setting
-
© Siemens AG 2011 All Rights Reserved