Parameters
List of Parameters
r0053.0...11
CO/BO: Status word 2 / ZSW 2
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays status word 2.
Bit field:
Bit
Signal name
00
DC braking active
01
|n_act| > p1226 (n_standstill)
02
|n_act| > p1080 (n_min)
03
I_act >= p2170
04
|n_act| > p2155
05
|n_act| <= p2155
06
|n_act| >= r1119 (n_set)
07
Vdc <= p2172
08
Vdc > p2172
09
Ramp-up/ramp-down completed
10
Technology controller output at the lower
limit
11
Technology controller output at the upper
limit
Caution:
p2081 is used to define the signal sources of the PROFIdrive status word interconnection.
Note:
The following status bits are displayed in r0053:
Bit 00: r1239 Bit 8
Bit 01: r2197 Bit 5 (negated)
Bit 02: r2197 Bit 0 (negated)
Bit 03: r2197 Bit 8
Bit 04: r2197 Bit 2
Bit 05: r2197 Bit 1
Bit 06: r2197 Bit 4
Bit 07: r2197 Bit 9
Bit 08: r2197 Bit 10
Bit 09: r1199 Bit 2 (negated)
Bit 10: r2349 Bit 10
Bit 11: r2349 Bit 11
1-32
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: Unsigned16
Data set: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
© Siemens AG 2011 All Rights Reserved