Siemens CU240B-2 Parameter Manual page 372

Table of Contents

Advertisement

Parameters
List of Parameters
r9772.0...20
CO/BO: SI status (processor 1) / SI status P1
CU240E-2
Access level: 2
CU240E-2 DP
Can be changed: -
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
-
Description:
Displays the Safety Integrated status on processor 1.
Bit field:
Bit
Signal name
00
STO selected on processor 1
01
STO active on processor 1
09
STOP A cannot be acknowledged, active
10
STOP A active
15
STOP F active
16
STO cse: Safety comm. mode
17
STO cause selection via terminal (Basic
Functions)
18
STO cause: Selection via motion monitoring
functions
19
STO cause actual value missing
20
STO cause selection PROFIsafe (Basic
Functions)
Dependency:
Refer to: r9872
Note:
Re bit 00:
When STO is selected, the cause is displayed in bits 16 ... 20.
Re bit 18:
When the bit is set, STO is selected via PROFIsafe.
Re bit 19:
For the drive-integrated motion monitoring functions, due to OFF2, no actual value sensing possible.
r9773.0...31
CO/BO: SI status (processor 1 + processor 2) / SI status P1+P2
CU240E-2
Access level: 2
CU240E-2 DP
Can be changed: -
CU240E-2 DP F
Units group: -
CU240E-2 F
Min
-
Description:
Displays the Safety Integrated status on the drive (processor 1 + processor 2).
Bit field:
Bit
Signal name
00
STO selected in drive
01
STO active in drive
31
Shutdown paths must be tested
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
1-372
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
Data type: Unsigned32
Data set: -
Factory setting
-
0 signal
No
No
No
© Siemens AG 2011 All Rights Reserved
FP
2810
2810
2802
2802
2802
-
-
-
-
-
FP
2804
2804
2810

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f