Parameters
List of Parameters
p1503[0...n]
CI: Torque setpoint / M_set
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the torque setpoint for torque control.
Note:
A change is made to closed-loop torque control if, in p1300, closed-loop torque control was selected or if the selec-
tion was made using the changeover source in p1501.
it is also possible to change over in operation using p1501.
r1508
CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
Access level: 2
Can be changed: -
Units group: 7_1
Min
- [Nm]
Description:
Displays the torque setpoint before entering the supplementary torque.
For closed-loop speed control, r1508 corresponds to the speed controller output; for closed-loop torque control,
r1508 corresponds to the torque setpoint of the signal source assigned in p1503.
p1511[0...n]
CI: Supplementary torque 1 / M_suppl 1
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for supplementary torque 1.
p1512[0...n]
CI: Supplementary torque 1 scaling / M_suppl 1 scal
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the supplementary torque 1.
p1513[0...n]
CI: Supplementary torque 2 / M_suppl 2
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for supplementary torque 2.
1-210
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
Calculated: -
Scaling: p2003
Unit selection: p0505
Max
- [Nm]
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: p2003
Unit selection: -
Max
-
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
- [Nm]
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
Data type: U32 / FloatingPoint32
Data set: CDS, p0170
Factory setting
0
© Siemens AG 2011 All Rights Reserved