r7843[0...20]
Memory card serial number / Mem_card ser.no
Access level: 4
Can be changed: -
Units group: -
Min
-
Description:
Displays the actual serial number of the memory card.
The individual characters of the serial number are displayed in the ASCII code in the indices.
Notice:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
Note:
Example: displaying the serial number for a memory card:
r7843[0] = 49 dec --> ASCII characters = "1" --> serial number, character 1
r7843[1] = 49 dec --> ASCII characters = "1" --> serial number, character 2
r7843[2] = 49 dec --> ASCII characters = "1" --> serial number, character 3
r7843[3] = 57 dec --> ASCII characters = "9" --> serial number, character 4
r7843[4] = 50 dec --> ASCII characters = "2" --> serial number, character 5
r7843[5] = 51 dec --> ASCII characters = "3" --> serial number, character 6
r7843[6] = 69 dec --> ASCII characters = "E" --> serial number, character 7
r7843[7] = 0 dec --> ASCII characters = " " --> serial number, character 8
...
r7843[19] = 0 dec --> ASCII characters = " " --> serial number, character 20
r7843[20] = 0 dec
Serial number = 111923E
r7901[0...43]
Sampling times / t_sample
Access level: 4
Can be changed: -
Units group: -
Min
- [µs]
Description:
Displays the sampling times currently present on the drive unit.
For r7901[x] = 0, the following applies: The time slice is not active.
r7903
Hardware sampling times still cannot be assigned / HW t_samp free
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by OA applications such as DCC (Drive Control Chart) or FBLOCKS (free
function blocks).
Note:
OA: Open Architecture
r8570[0...39]
Macro drive object / Macro DO
Access level: 1
Can be changed: -
Units group: -
Min
-
Description:
Displays the macro file saved in the appropriate directory on the memory card/device memory.
Dependency:
Refer to: p0015
Note:
For a value = 9999999, the following applies: The read operation is still running.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
- [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of Parameters
Data type: Unsigned8
Data set: -
Factory setting
-
Data type: FloatingPoint32
Data set: -
Factory setting
- [µs]
Data type: Unsigned16
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
1-331

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f

Table of Contents