p9556
SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.00 [ms]
Description:
Sets the delay time for the safe pulse suppression after STOP B.
In the case of encoderless motion monitoring functions with brake ramp monitoring (p9506 = 1), the parameter has
no effect.
Dependency:
Refer to: p9560
Refer to: C01701
p9558
SI Motion acceptance test mode time limit (processor 1) / SI Mtn acc t P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
5000.00 [ms]
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: C01799
p9559
SI Motion forced checking procedure timer (processor 1) / SI Mtn dyn timer
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.00 [h]
Description:
Sets the time interval for carrying out the forced checking procedure and testing the safety motion monitoring func-
tions integrated in the drives.
Within the parameterized time, the safety functions must have been tested at least once (including de-selection of
the "STO" function).
This monitoring time is reset each time the test is carried out.
The signal source to initiate the forced checking procedure is set in p9705.
Dependency:
Refer to: p9705
Refer to: A01697, C01798
Note:
STO: Safe Torque Off
p9560
SI Motion pulse suppression shutdown speed (processor 1) / SI Mtn IL v_sh P1
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
10.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B, the pulses are suppressed by changing to STOP A).
Dependency:
Refer to: p9556
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
600000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
100000.00 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
9000.00 [h]
Calculated: -
Scaling: -
Unit selection: -
Max
6000.00 [rpm]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: -
Factory setting
600000.00 [ms]
Data type: FloatingPoint32
Data set: -
Factory setting
40000.00 [ms]
Data type: FloatingPoint32
Data set: -
Factory setting
8.00 [h]
Data type: FloatingPoint32
Data set: -
Factory setting
10.00 [rpm]