Parameters
List of Parameters
p10006
SI acknowledgement internal event F-DI (processor 1) / SI ackn int evt P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0
Description:
Select a safety-relevant digital input for the signal "acknowledge internal event" (internal fault).
The falling edge at this input resets the status "internal event" in the drive.
Value:
0:
1:
2:
3:
255:
Dependency:
Refer to: p10106
Refer to: A01666, A30666
Note:
F-DI: Failsafe Digital Input
If value = 0:
No terminal assigned, acknowledge input has a static zero value.
p10017
SI digital inputs debounce time (processor 1) / SI DI t_debounceP1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.00 [ms]
Description:
Sets the debounce time for digital inputs.
The debounce time is accepted rounded off to whole milliseconds.
The debounce time acts on the following digital inputs:
- Fail-safe digital inputs (F-DI).
- Single-channel digital inputs (DI).
- Single-channel digital input 2 (DI 2, read back input for the forced checking procedure).
Dependency:
Refer to: p10117
Note:
Example:
Debounce time = 1 ms: Fault pulses of 1 ms are filtered; only pulses longer than 2 ms are processed.
Debounce time = 3 ms: Fault pulses of 3 ms are filtered; only pulses longer than 4 ms are processed.
The debounce result can be read in r10051.
1-384
Statically active
F-DI 0
F-DI 1
F-DI 2
Statically inact
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
255
Calculated: -
Scaling: -
Unit selection: -
Max
100.00 [ms]
Data type: Integer16
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
1.00 [ms]