p9389
SI Motion voltage tolerance acceleration (processor 2) / SI Mtn U tol P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
10.00 [%]
Description:
Sets the voltage tolerance for suppressing acceleration peaks.
Increasing this percentage value means that voltage peaks will need to have a higher amplitude during acceleration
procedures if they are not to affect actual value sensing.
- The value must be increased if C30711 has occurred with message value 1042.
- The value must be lowered if acceleration procedures have led to an excessive Safety actual velocity.
Dependency:
Refer to: C30711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
r9398[0...1]
SI Motion actual checksum SI parameters (processor 2) / SI Mtn act CRC P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
-
Description:
Displays the checksum over the checked Safety Integrated parameters of the motion monitoring functions (actual
checksum) on processor 2.
Index:
[0] = Checksum over SI parameters for motion monitoring
[1] = Checksum over SI parameters with hardware reference
Dependency:
Refer to: p9399
p9399[0...1]
SI Motion setpoint checksum SI parameters (processor 2) / SI Mtn setp CRC P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0000 hex
Description:
Sets the checksum over the checked Safety Integrated parameters of the motion monitoring functions (actual
checksum) on processor 2.
Index:
[0] = Checksum over SI parameters for motion monitoring
[1] = Checksum over SI parameters with hardware reference
Dependency:
Refer to: r9398
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00 [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
FFFF FFFF hex
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: -
Factory setting
100.00 [%]
Data type: Unsigned32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
0000 hex
1-343

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f