p9360
SI Motion pulse suppression shutdown speed (processor 2) / SI Mtn IL n_sh P2
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
10.00 [rpm]
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are suppressed (by changing to STOP
A).
Dependency:
Refer to: p9356, p9560
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SS1: Safe Stop 1
p9363[0...3]
SI Motion SLS stop response (processor 2) / SI Mtn SLS stop P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0
Description:
Sets the stop response for the function "Safely-Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value:
0:
1:
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9331, p9563
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SLS: Safely-Limited Speed
p9364
SI Motion SDI tolerance (processor 2) / SI Mtn SDI tol P2
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
0.001 [°]
Description:
Sets the tolerance for the function "Safe motion direction" (SDI). This motion in the monitored direction is still per-
missible before an alarm is initiated.
Dependency:
Refer to: p9365, p9366
Refer to: C30716
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive. Sets the tolerance
for the function "Safe motion direction" (SDI).
Note:
SDI: Safe Direction (safe motion direction)
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
STOP A
STOP B
Calculated: -
Scaling: -
Unit selection: -
Max
6000.00 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
360.000 [°]
Parameters
List of Parameters
Data type: FloatingPoint32
Data set: -
Factory setting
10.00 [rpm]
Data type: Integer16
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
12.000 [°]
1-339