Parameters
List of Parameters
p9563[0...3]
SI Motion SLS-specific stop response (processor 1) / SI Mtn SLS stop P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0
Description:
Sets the SLS-specific stop response for the function "Safely-Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value:
0:
1:
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9531
Note:
SLS: Safely-Limited Speed
p9564
SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
0.001 [°]
Description:
Sets the tolerance for the function "Safe motion direction" (SDI). This motion in the monitored direction is still per-
missible before an alarm is initiated.
Dependency:
Refer to: p9565, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
p9565
SI Motion SDI delay time (processor 1) / SI Mtn SDI t P1
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.00 [ms]
Description:
Sets the delay time for the function "Safe motion direction" (SDI). When selecting the SDI function, motion in the
monitored direction is permissible as a maximum for this time; this means that this time can be used for braking
existing motion.
Dependency:
Refer to: p9564, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
1-354
STOP A
STOP B
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
360.000 [°]
Calculated: -
Scaling: -
Unit selection: -
Max
600000.00 [ms]
Data type: Integer16
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
12.000 [°]
Data type: FloatingPoint32
Data set: -
Factory setting
100.00 [ms]