p9370
SI Motion acceptance test mode (processor 2) / SI Mtn acc_mod P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: U, T
Units group: -
Min
0000 hex
Description:
Setting to select and de-select the acceptance test mode.
Value:
0:
172:
Dependency:
Refer to: p9358, r9371
Refer to: C01799
Note:
Acceptance test mode can only be selected if the motion monitoring functions, which are integrated in the drives,
are enabled (p9601.2/p9801.2).
r9371
SI Motion acceptance test status (processor 2) / SI Mtn acc_stat P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: -
Units group: -
Min
0000 hex
Description:
Displays the status of the acceptance test mode.
Value:
0:
12:
13:
15:
172:
Dependency:
Refer to: p9358, p9370
Refer to: C01799
p9381
SI Motion brake ramp reference value (processor 2) / SI Mtn ramp ref P2
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
600.0000 [rpm]
Description:
Sets the reference value to define the brake ramp.
The rate of rise of the brake ramp depends upon p9381 (reference value) and p9383 (monitoring time).
Dependency:
Refer to: p9382, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9382
SI Motion brake ramp delay time (processor 2) / SI Mtn rp t_del P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
10000.00 [µs]
Description:
Sets the delay time for monitoring the brake ramp.
Monitoring of the brake ramp starts once the delay time has elapsed.
Dependency:
Refer to: p9381, p9383
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
[00 hex] De-select the acceptance test mode
[AC hex] Select the acceptance test mode
[00 hex] Acc_mode inactive
[0C hex] Acc_mode not possible due to POWER ON fault
[0D hex] Acc_mode not possible due to incorrect ID in p9370
[0F hex] Acc_mode not possible due to expired Acc_timer
[AC hex] Acc_mode active
Calculated: -
Scaling: -
Unit selection: -
Max
00AC hex
Calculated: -
Scaling: -
Unit selection: -
Max
00AC hex
Calculated: -
Scaling: -
Unit selection: -
Max
24000.0000 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
99000000.00 [µs]
Parameters
List of Parameters
Data type: Integer16
Data set: -
Factory setting
0000 hex
Data type: Integer16
Data set: -
Factory setting
-
Data type: FloatingPoint32
Data set: -
Factory setting
1500.0000 [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
250000.00 [µs]
1-341