p20235
LIM 0 run sequence / LIM 0 RunSeq
Access level: 3
Can be changed: T
Units group: -
Min
0
Description:
Setting parameter for the run sequence of instance LIM 0 within the run-time group set in p20234.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20236
CI: LIM 1 input X / LIM 1 input X
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source of input quantity X of instance LIM 1 of the limiter.
p20237
LIM 1 upper limit value LU / LIM 1 upper lim LU
Access level: 3
Can be changed: T
Units group: -
Min
-340.28235E36
Description:
Setting parameter for the upper limit value LU of instance LIM 1 of the limiter.
p20238
LIM 1 lower limit value LL / LIM 1 lower lim LL
Access level: 3
Can be changed: T
Units group: -
Min
-340.28235E36
Description:
Setting parameter for the lower limit value LL of instance LIM 1 of the limiter.
r20239
CO: LIM 1 output Y / LIM 1 output Y
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Display parameter for the limited output quantity Y of instance LIM 1 of the limiter.
r20240
BO: LIM 1 input quantity at the upper limit QU / LIM 1 QU
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Display parameter of instance LIM 1 of limiter QU (upper limit reached), i.e. QU = 1 for X >= LU.
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of Parameters
Data type: Unsigned16
Data set: -
Factory setting
640
Data type: U32 / FloatingPoint32
Data set: -
Factory setting
0
Data type: FloatingPoint32
Data set: -
Factory setting
0.0000
Data type: FloatingPoint32
Data set: -
Factory setting
0.0000
Data type: FloatingPoint32
Data set: -
Factory setting
-
Data type: Unsigned32
Data set: -
Factory setting
-
1-437