Siemens CU240B-2 Parameter Manual page 340

Table of Contents

Advertisement

Parameters
List of Parameters
p9365
SI Motion SDI delay time (processor 2) / SI Mtn SDI t P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0.00 [µs]
Description:
Sets the delay time for the function "Safe motion direction" (SDI). When selecting the SDI function, motion in the
monitored direction is permissible as a maximum for this time; this means that this time can be used for braking
existing motion.
Dependency:
Refer to: p9364, p9366
Refer to: C30716
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SDI: Safe Direction (safe motion direction)
p9366
SI Motion SDI stop response (processor 2) / SI Mtn SDI Stop P2
CU240E-2 DP F
Access level: 3
CU240E-2 F
Can be changed: C(95)
Units group: -
Min
0
Description:
Sets the stop response for the function "Safe motion direction" (SDI).
This setting applies to both directions of motion.
Value:
0:
1:
Dependency:
Refer to: p9364, p9365
Refer to: C30716
Note:
SDI: Safe Direction (safe motion direction)
p9368
SI Motion SAM velocity limit (processor 2) / SI Mtn SAM v_limP2
Access level: 3
CU240E-2 DP F
Can be changed: C(95)
CU240E-2 F
Units group: -
Min
0.00 [rpm]
Description:
Sets the velocity tolerance limit for the "SAM" function.
SAM is de-activated once the set velocity limit has been undershot.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
For p9568 = p9368 = 0, the following applies:
The value in p9546/p9346 (SSM) is applied as the velocity limit for SAM.
1-340
STOP A
STOP B
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Calculated: -
Scaling: -
Unit selection: -
Max
600000000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
1
Calculated: -
Scaling: -
Unit selection: -
Max
1000.00 [rpm]
Data type: FloatingPoint32
Data set: -
Factory setting
100000.00 [µs]
Data type: Integer16
Data set: -
Factory setting
1
Data type: FloatingPoint32
Data set: -
Factory setting
0.00 [rpm]
© Siemens AG 2011 All Rights Reserved

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120Cu240e-2Cu240b-2 dpCu240e-2 dpCu240e-2 fCu240e-2 dp f