Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
Procedure
1. Use either benzine or solvent to remove the anti-corrosion protection from the shaft ends
and flanges or remove the applied protective skin.
2. Fit the drive input and output elements to the shafts. Fasten the elements when necessary.
You have now fitted the input or output element.
11.3.12

Removing and installing the protection cover

The protection cover of the hollow shaft is delivered ready-fitted to the gearbox flange.
Remove the protection cover to install the output shaft.
The plastic protection cover of the hollow shaft is supplied loose as kit.
Figure 11-16 Protection cover for hollow shaft
Procedure
Premounted protection cover
1. Release the screws ① and remove the protection cover ② together with the flat gasket or O-
ring ③.
2. Mount the output shaft.
3. Use a suitable cleaning agent to clean the contact surface of the protection cover ② on the
gearbox.
4. Ensure that the flat seal or the O-ring ③ is correctly seated.
5. Apply medium-strength adhesive, e.g. Loctite 243 to the screws ①.
6. Screw on the protection cover ②.
7. Protect all remaining bare areas with a suitable permanent anti-corrosive agent.
You have now installed the protection cover for operation.
414
Bolt
Protection cover
Flat seal / O-ring
Gearbox housing
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
SINAMICS G115D distributed drive