Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
11.3.31
Mounting positions
11.3.31.1
General notes on mounting positions
Only operate the gearbox in the mounting position specified on the rating plate. This ensures
that the correct quantity of lubricant is provided. The symbols are shown for the standard
mounting position.
Note
Gearbox sizes 19 and 29
Gearbox sizes 19 and 29 are lubricated for life. There is no opening to check the oil level.
In mounting positions M2 and M4 the gearboxes are equipped with a breather valve.
C29 has a breather valve in all mounting positions.
Description of the symbols:
Venting
A, B
*
①
②
③
448
Position of insert shaft / solid shaft
On opposite side
Oil level check not possible for tandem gearbox (main gearbox a)
Two-stage gearbox
Three-stage gearbox
Oil level
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Oil drain
SINAMICS G115D distributed drive