Checking The Oil Level - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
Note
Oil specifications
Refer to the rating plate for the type of oil, oil viscosity and quantity of oil required.
For oil compatibility, see Recommended lubricants (Page 444).
Note
Gearbox sizes 19 and 29
Gearbox sizes 19 and 29 are lubricated for life. There is no opening to check the oil level. An
oil change is not required.
In mounting positions M2 and M4 the gearboxes are equipped with a breather valve.
C29 has a breather valve in all mounting positions.
11.3.24.2

Checking the oil level

NOTICE
The gearbox oil volume changes depending on the temperature
If the temperature rises, the volume increases. Where temperature differences and filling
quantities are significant, the volume difference can amount to several liters.
The oil level must therefore be checked while still slightly warm, approximately 30 minutes
after switching off the drive unit.
Figure 11-29 Oil level in the gearbox housing
Table 11- 45 Minimum and maximum fill levels x
Oil level hole
G 1/8"
G 1/4"
G 3/8"
G 3/4"
436
Specified oil level
Maximum oil level
Minimum oil level
∅d2
[mm]
14
18
22
32
Fill level x
[mm]
2.5
3
4
7
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Tightening torque
[Nm]
10
10
25
50
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading

Table of Contents