10.2.4
Technical data of braking resistors
Technical data of integrated braking resistor
G115D wall-mounted converter
Frame size
FSA
FSB
Peak power at 10% cycle time of a 120s cycle.
1)
10.2.5
Load cycles and overload capabilities
Overload capability is the property of the converter to temporarily supply a current that is
higher than the rated current to accelerate a load.
Definitions
Base load
Constant load between the accelerating phases of the converter
HO base load input current
Permissible input current for a "High Overload" load cycle
HO base load output current
Permissible output current for a "High Overload" load cycle
HO base load power
Rated power based on the HO base load output current
If not specified otherwise, the power and current data in the technical data always refer to a
load cycle according to High Overload.
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
10.2 Technical data of the G115D wall-mounted converter
Rated power
Resistance
0.37 kW to 1.5 kW
350 Ω
2.2 kW to 4 kW
175 Ω
Integrated braking resistor
Continuous braking
Peak braking power
power
10 W
100 W
10 W
100 W
Technical data
1)
343