Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
The oil level must be between the lower ② and upper ③ marks on the oil dipstick ①.
After checking, screw the oil dipstick ① in again hand-tight. The oil dipstick ① can remain
screwed in during operation.
Rectify the oil level if necessary and check it again.
11.3.24.5

Checking the oil quality

Visible signs show effects on the oil. Fresh oil is clear to the eye, and has a typical smell and a
specific product color. Clouding or a flocculent appearance indicates water and / or
contamination. A dark or black color indicates residue, serious thermal decomposition or
contamination.
Observe the symbols in the diagrams of the Mounting positions (Page 448):
Venting
Procedure
1. Allow the geared motor to run for a short time. Wear and contaminant particles are visible in
the oil shortly after shutting down.
2. Switch off the power supply to the drive unit.
3. Unscrew the sealing element at one of the points marked with the symbols listed above.
4. Remove some oil, using a suction pump and a flexible hose, for example.
5. Check the state of the sealing ring on the sealing element. When required, replace the
sealing ring.
6. Seal the gearbox with the sealing element.
7. Check the oil for abnormalities. Change the oil immediately if you determine any
abnormalities, see General safety notes for changing the oil (Page 439).
You have now checked the oil quality.