Terminal layout of the Wiring Module
If you use a glanded variant of the converter, you must wire all the necessary terminals inside
the Wiring Module.
NOTICE
Device damage due to alteration to the factory connections
For the motor-mounted converter, the motor terminals inside the Wiring Module are already
wired up in the factory. Any alteration to the factory connections can result in device
malfunctions or damage.
• Do not alter the motor connections of the motor-mounted converter unless otherwise
The figures below give an overview of the terminals on the motor-mounted converter and
the wall-mounted converter respectively.
Note that the converters of glanded variant provide no cable glands but blanking caps at
delivery for all glanded interfaces.
Motor-mounted converter
① Line supply terminals - L1, L2, L3
② Motor power terminals - U, V, W
③ Digital inputs/outputs terminals - DI0~DI3,
④ Switched/unswitched 24 V power supply
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
explicitly instructed.
DIO24, DIO25
terminals - 2L+, 2M / 1L+, 1M
Protective earth
4.7 Overview of the converter interfaces
⑤ DIP switches - DIP1, DIP2
⑥ Motor temperature sensor terminals - T+, T-
⑦ Braking resistor terminals - DCP, PB
⑧ 180 V DC EM brake terminals - EM+, EM-
Wiring
55