Connecting The Cables In The Terminal Box - Siemens SINAMICS G115D Operating Instructions Manual

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Figure 11-8
Table 11- 12 Direction of rotation of the geared motor when viewing the output shaft
Gearbox type
Z
D
FZ
FD
B
K
C
11.2.10.5

Connecting the cables in the terminal box

Note
Direct contact between the cable lug surfaces and the contact nuts ensures that the
connection can carry current.
In the case of terminals with terminal clamps, distribute the conductors in such a way that
the clamping heights are about the same on both sides of the fillet. This method of
connection requires a single conductor to be bent into a U shape or connected with a cable
lug. The same applies to the inner and outer terminals of the ground conductor.
Select the cable lug size according to the required cable cross-section and stud size. A
sloped / angular arrangement is permitted if the required clearances and creepage distances
are maintained.
Remove the insulation from the conductor ends so that the remaining insulation is almost
long enough to reach the cable lug.
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
View of output shaft
View of drive shaft / motor shaft
Direction of rotation
View of
Output shaft
DE of the output shaft
NDE of the output shaft
DE of the output shaft
NDE of the output shaft
DE of the output shaft
NDE of the output shaft
Additional information on the SIMOGEAR geared motor
Direction of rotation
Output shaft
Clockwise
11.2 Specific data motor
Input shaft
Clockwise
Counterclockwise
Clockwise
Counterclockwise
Clockwise
Counterclockwise
Counterclockwise
Counterclockwise
Clockwise
Counterclockwise