Advanced commissioning
6.8 Conveyor technology control functions
Parameter
p1113[0...n]
p3384
p3385
p3386
p3387
p3388
p3389
p3390
p3391
p3392
p3393
p3394
p3395
r3396.0...16
p3397
176
Description
BI: Setpoint inversion
BI: Stop sensor positive direction
signal source
BI: Stop sensor negative direction
signal source
BI: Stop sensor center signal
source
BI: Low speed sensor positive
direction signal source
BI: Low speed sensor negative
direction signal source
BI: Low speed sensor center signal
source
BI: Stop/low speed sensor bypass
signal source
BI: Stop/low speed sensor bypass
manual operation signal source
End position shutdown activation
Conveyor technology application
selection
Stop sensor evaluation type
Low speed sensor evaluation type
CO/BO: Conveyor technology
application status
CI: Rapid traverse setpoint signal
source
Setting
Signal source for inverting the setpoint.
1 signal: Invert setpoint
The factory setting depends on the converter
fieldbus interface.
Sets the signal source of the stop sensor for the
positive direction.
Factory setting: 0
Sets the signal source of the stop sensor for the
negative direction.
Factory setting: 0
Sets the signal source of the stop sensor for the
middle position.
Factory setting: 0
Sets the signal source of the low speed sensor for
the positive direction.
Factory setting: 0
Sets the signal source of the low speed sensor for
the negative direction.
Factory setting: 0
Sets the signal source of the low speed sensor for
the middle position.
Factory setting: 0
Sets the signal source for bypassing the stop and
low speed sensors.
1 signal: The stop and low speed sensors are not
taken into account.
The factory setting depends on the converter
fieldbus interface.
Sets the signal source for bypassing the stop and
low speed sensors in the "manual operation"
mode.
Factory setting: 8559.4
= 0: End position shutdown deactivated. Travel
can be continued in both directions.
= 1: End position shutdown activated (factory
setting). Travel can only be continued in the op-
posite direction.
Selects the conveyor technology application.
Factory setting: 0
= 1: Input signal high level triggered
= 2: Input signal low level triggered (factory set-
ting)
= 3: Input signal 0→1 edge triggered
= 4: Input signal 1→0 edge triggered
See p3394.
Factory setting: 4
Displays the status of the conveyor technology
application.
Sets the signal source of the high speed setpoint.
The setpoint for the input is interconnected with
the main setpoint p1070.