Siemens SINAMICS G115D Operating Instructions Manual page 133

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Table 6- 2
No.
1
2
3
4
5
6
7
Table 6- 3
Byte Bit
1
2
Assembly Object, Instance Number: 4 hex
Supported services
Class
SINAMICS G115D distributed drive
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
Instance Attribute
Service
Type
Name
get
UINT16
Vendor ID
get
UINT16
Device Type
- ODVA AC Drive
- Siemens Drive
get
UINT16
Product code
get
UINT16
Revision
get
UINT16
Status
get
UINT32
Serial number
get
Short
Product name
String
Explanation of No. 5 of the previous table
Name
0
Owned
1
2
Configured
3
4 ... 7
Extended Device
Status
8 ... 11
12 ... 15
• Get Attribute single
Value/explanation
1251
02 hex
12 hex
r0964[1]
The versions should match the EDS file
See the following table
bits 0 ... 19: consecutive number;
bits 20 ... 23: Production identifier
bits 24 ... 27: Month of manufacture (0 = Jan, B =
Dec)
Bits 28 ... 31: Year of manufacture (0 = 2002)
Max. length 32 bytes
Description
0: Converter is not assigned to any master
1: Converter is assigned to a master
Reserved
0: Ethernet/IP basic settings
1: Modified Ethernet/IP settings
For G120, always = 1
Reserved
0: Self-test or status not known
1: Firmware update active
2: At least one I/O connection with error
3: No I/O connections
4: Incorrect configuration in the ROM
5: Fatal fault
6: At least one I/O connection is active
7: All I/O connections in the quiescent state
8 ... 15: Reserved
Not used
Reserved
Instance
Advanced commissioning
6.6 Drive control via Ethernet/IP
• Get Attribute single