Siemens SINAMICS G115D Operating Instructions Manual page 342

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Technical data
10.2 Technical data of the G115D wall-mounted converter
Safety Integrated
Property
Safety function
Environmental conditions
Property
Surrounding
temperature
Vibration and shock
Resistance to biologically active sub-
stances
Pollution degree
Relative humidity
Installation altitude
340
Explanation
STO, SIL2 / PL d / Category 3
STO fulfils the requirements of the following standards:
SIL 2 according to IEC61508, part 1 to 3 (2010)
PL d according to IEC61800-5-2 (2016)
Category 3 according to ISO13849 part 1 (2015)
The function STO corresponds to stop category 0 according to IEC60204 (2005)
Response time: 20 ms
The response time of the Safe Torque Off function is the time between selecting
the function and the function becoming active.
Probability of failures:
Probability of dangerous failure per hour: PFH < 25×10
PFH according to IEC 61800-5-2
Probability of dangerous failure on demand: PFD < 25×10
PFD according to IEC 61508
Mission time: 20 years
You may not operate converters with integrated safety functions for longer than
the mission time. The mission time starts when the device is delivered. The mission
time cannot be extended. This is the case even if a service department checks the
converter – or in the meantime, the converter was decommissioned.
Explanation
Storage
-40 °C to +70 °C, Class 1K4 according to IEC 60721-3-1, in product packaging
Transport
-40 °C to +70 °C, Class 2K4 according to IEC 60721-3-2, in transport packaging
Operation
FSA: -30 °C to +50 °C
FSB: -30 °C to +55 °C
Power derated by 3%/K when > 40 °C
Current derating as a function of the surrounding temperature (Page 345)
Transport
Class 1M2, test according to EN 60721-3-2, in product packaging
Operation
Class 3M2, test according to EN 60721-3-2
Class 3B1 according to EN 60721-3-3
Suitable for pollution degree 2 environment according to IEC 61800-5-1
< 95% (non-condensing, no icing, no salt spray)
Up to 1000 m above sea level without derating
Above 1000 m (up to 4000 m) with derating
Current derating as a function of the installation altitude (Page 344)
, Class 3K3 according to IEC 60721-3-3
1)
, Class 3K3 according to IEC 60721-3-3
1)
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
-9
-5
SINAMICS G115D distributed drive

Advertisement

Table of Contents
loading