Siemens SINAMICS G115D Operating Instructions Manual page 420

Distributed drive
Hide thumbs Also See for SINAMICS G115D:
Table of Contents

Advertisement

Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
Items ① to ⑤ are not included in the scope of supply.
Figure 11-19 Removing the hollow shaft with parallel key
Procedure
1. Remove the axial locking element from the hollow shaft.
2. Drive out the machine shaft using the disk ①, threaded block ②, parallel key ③, threaded
spindle ⑤ and hexagon nuts ④.
You have now removed the hollow shaft with parallel key.
Design suggestion for threaded block and disk
Gearbox
B
B, C
B, F
C
B, K, F, C
B
B
C
K, F, C
B
418
Disk
Threaded block
Parallel key
Size
Hollow
shaft ∅
[mm]
19
20
29
20
29
25
39
25
30
35
40
49
30
35
40
Hexagon nut
Lead screw
b10
b11
b12
d10
[mm]
[mm]
[mm]
[mm]
3
15
10
19.9
3
15
10
19.9
3
15
10
24.9
3
15
10
24.9
6
15
10
29.9
6
15
10
34.9
6
15
10
39.9
6
15
10
29.9
6
15
10
34.9
6
15
10
39.9
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
d11
s11
t
u
max
[mm]
[mm]
[mm]
[mm]
10
M6
22.5
6
10
M6
22.5
6
16
M10
28
8
16
M10
28
8
18
M10
33
8
24
M12
38
10
28
M16
43
12
18
M10
33
8
24
M12
38
10
28
M16
43
12
SINAMICS G115D distributed drive