Unless contractually agreed otherwise, the guarantee period for the standard preservative
lasts 6 months from the date of delivery.
In the case of storage in transit over 6 months, special arrangements must be made for
preservation. Please contact Technical Support.
Store the gearbox or geared motor in dry, dust-free rooms that are maintained at a constant
temperature.
The storage location must be vibration- and shock-free.
The free shaft ends, sealing elements and flange surfaces must have a protective coating.
11.3.7.2

General notes for storage up to 36 months

Store the gearbox or geared motor in dry, dust-free rooms that are maintained at a constant
temperature. Special packing is then not necessary.
If such premises are not available, pack the gearbox or the geared motor in plastic film or air-
tight sealed film and materials. The films and materials must be able to accept moisture.
Cover them to provide protection against heat, direct sunlight and rain.
The permissible ambient temperature is -25 °C to +50 °C.
The life of the corrosion protection is 36 months from delivery.
11.3.7.3

Gearbox filled with operating oil and anti-corrosive agent

NOTICE
Damage to the gearbox caused by incorrect oil quantities
Check the oil level before commissioning.
Observe the information and procedures for Checking the oil level (Page 430).
The gearbox is filled with oil corresponding to the mounting position so that it is ready for
operation, and is sealed airtight using a screw plug or with a pressure breather valve with
transport fixture.
For storage up to 36 months, a VCI anti-corrosion agent (Volatile Corrosion Inhibitor) is
added.
11.3.7.4

Gearbox completely filled with oil

NOTICE
Damage to the gearbox caused by incorrect oil quantities
Prior to commissioning, remove excessive oil until it has the correct oil level.
Observe the information and procedures for Correcting the oil level (Page 430).