Additional information on the SIMOGEAR geared motor
11.3 Specific data gearbox
11.3.10

Gearboxes in foot or flange version

NOTICE
Impermissible housing loadings caused by incorrectly installed add-on elements
Do not subject the gearbox housing to excessive stress by adding add-on elements to the
foot or flange.
Add-on elements must not transmit forces, torques, and vibrations to the gearbox.
To prevent strains on the housing, fasten the gearbox only on the flange or the foot fastening
for force and torque transmission. Refer to Gearbox with foot mounting (Page 410).
The second mounting option (foot or flange) is intended for add-on elements, e.g. protection
covers with an intrinsic weight of up to max. 30 % of the weight of the gearbox.
11.3.11

Mounting an input or output element on the gearbox shaft

Risk of burns caused by hot parts
Do not touch the gearbox without protection.
NOTICE
Damage to shaft sealing rings caused by solvent
Avoid any contact of solvent or benzine with the shaft sealing rings.
NOTICE
Damage to shaft sealing rings caused by heating
Use thermal shields to protect shaft sealing rings from heating above 100 °C due to radiant
heat.
NOTICE
Premature wear or material damage due to misalignment
Misalignment caused by excessive angular or axis displacement to the connecting shaft
ends.
Ensure precise alignment of the individual components.
NOTICE
Damage caused by improper handling
Bearings, housing, shaft and locking rings are damaged due to improper handling.
Do not use impacts or knocks to force the input and output elements to be mounted onto
the shaft.
412
WARNING
Operating Instructions, 09/2020, FW V4.7 SP13, A5E48681219B
SINAMICS G115D distributed drive