Image Adj Param; Fuser Temp; Supplies Replace - Konica Minolta MagiColor 1600W Service Manual

Field service manual
Hide thumbs Also See for MagiColor 1600W:
Table of Contents

Advertisement

Field Service Ver. 1.0 Nov. 2008
15.4.6

IMAGE ADJ PARAM

Function
• Optimizes the image by varying the output value of the developing bias when an
image problem occurs due to the atmospheric pressure at high altitudes.
Use
• To adjust the developing when an image problem (uneven density) occurs in an envi-
ronment of low atmospheric pressure in places such as at high altitudes.
Setting
• The default setting is 0.
/procedure
NOTE
• When the setting has been changed, be sure to run a [REQUEST AIDC] pro-
cess.
See P.70
15.4.7

FUSER TEMP

Function
• To adjust the fusing heating temperature individually for each paper type so as to
ensure good fusing performance that varies with varying environmental conditions.
Use
• When fusing performance is poor, or wax streak or offset occurs when the type of
paper is changed or environmental conditions change.
• Use this function when curled paper, or paper misfeed as a result of the curled paper,
occurs under varying environmental conditions or depending on the type of paper
used.
Adjustment
• The default setting is 0.
Range
PLAIN PAPER: -10 / -5 / "0"
THICK1: -10 / -5 / "0"
THICK2: -10 / -5 / "0"
ENVELOPE: -10 / -5 / "0"
Adjustment
• If fusing performance is poor, increase the setting.
Instructions
• If wax streaks occur, decrease the setting.
• If offset is poor, decrease the setting.
• If curling of the paper occurs, decrease the setting.
Setting
1. Enter the SERVICE MENU.
/procedure
2. Select [FUSER TEMP] and press the Menu Select key.
3. Select the type of paper and press the Menu Select key.
4. Select desired setting value with the up key
Select key.
15.4.8

SUPPLIES REPLACE

A. TRANSFER ROLLER
Function
• Resets the transfer roller counter.
Use
• To use when the transfer roller has been replaced.
Setting
• The default setting is NO.
/procedure
1. Enter the SERVICE MENU.
2. Select [ADJUSTMENTS] - [SUPPLIES REPLACE] → [TRANSFER ROLLER], and
select [YES.]
3. Press the Menu Select key and reset the counter.
15. SERVICE MENU (magicolor 1650EN)
"0" / 1 / 2 / 3
/down key
"NO" / YES
and press the Menu