E1 CHECK THE PUMP MOTOR FOR CONTINUOUS OPERATION
Check the pump motor for continuous operation.
Is the pump motor running continuously?
E2 CHECK CIRCUIT 534 (YE/LG) FOR AN OPEN
Key in OFF position.
Disconnect: Anti-Lock Brake Control Module C135.
Measure the voltage between anti-lock brake control module C135
Pin 13, Circuit 534 (YE/LG), harness side, and ground.
Is the voltage greater than 10 volts?
E3 CHECK CIRCUIT 1205 (BK) FOR AN OPEN
Measure the resistance between anti-lock brake control module
C135 Pin 12, Circuit 1205 (BK), harness side and ground.
Is the resistance less than 5 ohms?
E4 CHECK THE PUMP MOTOR FOR OPERATION
Disconnect: Pump Motor Connector.
Connect a 30A fused heavy jumper wire between the positive battery
post and pump motor connector Pin 1 (component side); and
momentarily connect a heavy jumper between negative battery post
and pump motor connector Pin 2 (component side).
Yes
INSTALL a new
anti-lock brake
control module;
REFER to
Module
.
REPEAT the self-
test.
No
GO to
E2
.
Yes
GO to
E3
.
No
REPAIR the circuit.
CLEAR the DTCs.
REPEAT the self-
test.
Yes
GO to
E4
.
No
REPAIR the circuit.
CLEAR the DTCs.
REPEAT the self-
test.
Yes
INSTALL a new
anti-lock brake
control module;
REFER to
Module
.
REPEAT the self-
test.
No
INSTALL a new
HCU; REFER to
Hydraulic Control
Unit
. CLEAR the
DTCs. REPEAT

Hide quick links: