19
Positioning the Primary Charging Roller Cleaning Solenoid
Loosen the two screws used to fix the solenoid
arrow B so that the l in Figure 2-227 is 5.5 ±0.2 mm when the joint
solenoid support plate
Caution:
You must make this adjustment whenever you have replaced the solenoid.
3
.
B
Figure 2-227
STANDARDS AND ADJUSTMENTS
in place, and move the solenoid in the direction of the
is forced against the
2
a
= 5.5 ± 0.2
section of the
1
2–11