Dell Force10 C150 Configuration Manual page 381

Ftos configuration guide ftos 8.4.2.7 e-series terascale, c-series, s-series (s50/s25)
Hide thumbs Also See for Force10 C150:
Table of Contents

Advertisement

Boot the chassis with dual RPMs
When you boot the system with two RPMs installed, the RPM in slot R0 is the primary RPM by default.
Both RPMs should be running the same version of FTOS. You can configure either RPM to be the primary
upon the next chassis reboot using the command
Version compatibility between RPMs
In general, the two RPMs should have the same FTOS version. However, FTOS tolerates some degree of
difference between the two versions, as described in
RPM using the
Table 18-1. System Behavior with RPMs with Mismatched FTOS Versions
Mismatch Condition
different FTOS versions with
only first two digits matching
different FTOS versions with
first two digits not matching
different FTOS versions with
only first three digits matching
Message 2 FTOS Version Incompatibility Error
************************************************
*
*
Warning !!!
*
* ----------------------------------------------
*
*
Incompatible SW Version detected !!
*
*
This RPM -> 7.4.2.0
*
Peer RPM -> 7.4.1.0
*
************************************************
00:00:12: %RPM0-U:CP %IRC-4-IRC_VERSION: Current RPM 7.4.2.0 Peer RPM 7.4.1.0 - Different
software version detected
00:00:12: %RPM0-U:CP %IRC-6-IRC_COMMUP: Link to peer RPM is up
00:00:14: %RPM0-U:CP %RAM-6-ELECTION_ROLE: RPM0 is transitioning to Primary RPM.
Message 3 Boot Failure on Standby RPM
System failed to boot up. Please reboot the chassis !!!
00:12:46: %RPM1-U:CP %TME-0-RPM BRINGUP FAIL: FTOS failed to bring up the system
Communication between RPMs is not up, check the software version and reboot chassis.
FTOS(standby)(bootfail)#
show redundancy
command as shown in
Example
Primary: 7.4.2.0
Standby: 7.4.1.0
Primary: 7.6.1.0
Standby: 7.5.1.0
Primary: 7.4.2.0
Standby: 7.4.2.1
Warning !!!
Warning !!!
redundancy primary
Table
18-1. View the configuration loaded on each
Figure
18-1.
Behavior
The link to the standby RPM is up, and FTOS block syncs only the
startup-config. The failover type is warm upgrade. FTOS displays
Message
2.
The link to the standby RPM is down, and the standby RPM is in a boot
loop. FTOS displays
Message 3
The link to the peer RPM is up, and FTOS performs a complete block
sync. The failover type is hot failover. FTOS displays
from CONFIGURATION mode.
and a boot fail prompt.
Message
High Availability | 381