Pin assignment RF382R Scanmode RS232 interface
You can connect the RF382R Scanmode reader via the internal RS232 interface or via a higher-level system. Pay attention
to the correct assignment of the pins.
Table 3 Connector and reader pin assignment
Pin
Display elements of the RF382R Scanmode reader
Table 4 LED display elements on the reader
Color
Meaning
Green
Operating voltage present, reader ready for operation
Yellow
Transponder present
Red
Red LED for error display is activated permanently if correct operation of the reader cannot be guaranteed
(e. g. faulty start, checksum error during operation).
2
Pin
Device end 8-pin M12
1
2
3
4
5
6
7
8
Assignment
+ 24 V
RXD
0 V
TXD
must not be connected
must not be connected
must not be connected
Ground (shield)
J31069-D0214-U001-A1-7618, 10/2009
SIMATIC RF382R Scanmode