Cisco AJ732A - MDS 9134 Fabric Switch Messages Manual page 413

Cisco mds 9000 family system messages reference (ol-15956-01, april 20078)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
System Messages and Recovery Procedures for the Cisco MDS 9000 Family
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Error Message SYSMGR-2-SAVE_RUNTIME_DB_FAILED:
fabric switch upgrade
Error Message SYSMGR-2-SHUTDOWN_FAILURE: Unable to set signal handler for graceful
shutdown: [chars] (error-id [hex]).
Error Message
configuration. Please try again later.
Error Message
SIGKILL causing supervisor to reset.
Error Message
OL-15956-01
This message indicates that the runtime database could not be saved for the fabric
Explanation
switch upgrade.
Recommended Action
If you purchased Cisco support through a Cisco reseller, contact the reseller
directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support.
Cisco MDS SAN-OS Release 3.1(1).
Introduced
Graceful shutdown has failed.
Explanation
No action is required.
Recommended Action
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
SYSMGR-2-SHUTDOWN_REJECT: The System Manager is busy saving the
Explanation
Shutdown was rejected because the system manager is busy.
Retry the graceful shutdown.
Recommended Action
Cisco MDS SAN-OS Release 1.2(2a).
Introduced
SYSMGR-2-SIGKILL_FAILURE: Service "[chars]" failure to respond to
Resetting the supervisor because service failed to respond to SIGKILL sent to it by
Explanation
system manager.
If you purchased Cisco support through a Cisco reseller, contact the reseller
Recommended Action
directly. If you purchased support directly from Cisco Systems, contact Cisco Technical Support.
Cisco MDS SAN-OS Release 1.3(1).
Introduced
SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
Explanation
The standby supervisor does not complete its boot procedure (that is, it does not reach
the login prompt on the local console) three to six minutes after the loader has been loaded by the
BIOS. This is usually caused by boot variables not properly set for the standby supervisor. This can
also be caused by a user intentionally interrupting the boot procedure at the loader prompt (by means
of pressing ESC).
Connect to the local console of the standby supervisor. If the supervisor is at
Recommended Action
the loader prompt, try to use the boot command to continue the boot procedure. Otherwise, issue a
reload command for the standby supervisor from a MDS shell session on the active supervisor,
specifying the force-dnld option. Once the standby is online, fix the problem by setting the boot
variables appropriately.
failed (error-id [hex]).